JDB-240 Ball Screw Driven Slide (4 slides)
Ball Screw Driven Slide (4 slides) JDB-240

Dust-proof Standard Type
Motor Capacity: 1000W

Product Introduction
Applicable Motor AC-1000W/ 220V
Slide Track and Slide 25mm 2 Slide Tracks, 4 Slides
Specified Torque 3.2 N.m
Repetitive Precision ± 0.01mm
External Diameter of Ball Screw ø20mm, ø25mm, ø32mm, ø40mm
Pitch Lead Screw 5 mm 10 mm 20 mm 25 mm 32 mm 40 mm
Highest speed 250 mm/sec 500 mm/sec 1000 mm/sec 1250 mm/sec 1000 mm/sec 1800 mm/sec
Max. Weight Horizontal 210 kg 150 kg 110 kg 75 kg 50 kg 32 kg
Vertical 80 kg 65 kg 38 kg 25 kg 18 kg 15 kg
Sensor Model No. 671 x 3 pcs
Load Torque (N.m)  Ma: 458.8 N.m
 Ma: 464.3 N.m
 Ma: 464.3 N.m
JDB-240 Specification of Direct Type-1

       

1. The dimension of machine changes according to different motor and the motor lid is optional accessory.
Applicable motor: 400W, 750W, 1KW
2. We install the sensor outside (right or left side)

Note 1: Length changes basing on the motor
        The motor cover is optional, the picture is showing Mitsubishi 750W
        Applicable motor: 400W, 750W, 1KW
Note 2: Sensors are installed on the right or left side.

SENSOR outlet numbers are as follows:

  1. Positive limit +LS
  2. point HOME
  3. Negative limit -LS
JDB-240 Specification of Indirect Type-2L

1. Applicable motor: 400W, 750W, 1KW
2. We install the sensor on the right side

Note 1: Length changes basing on the motor
       Applicable motor: 400W, 750W, 1KW
Note 2: Sensors are installed on the right

SENSOR outlet numbers are as follows:

  1. Positive limit +LS
  2. Point HOME
  3. Negative limit -LS
JDB-240 Specification of Indirect Type-2R

1. Applicable motor: 400W, 750W, 1KW.
2. We install the sensor on the left side.

Note 1: Length changes basing on the motor
        Applicable motor: 400W, 750W, 1KW
Note 2: Sensors are installed on the left

SENSOR outlet numbers are as follows:

  1. Positive limit +LS
  2. Point HOME
  3. Negative limit -LS
JDB-240 Specification of Indirect Type-2B

1. Applicable motor: 400W, 750W, 1KW
2. We install the sensor outside (right or left side)

Note 1: The picture is showing Mitsubishi 750W
        Applicable motor: 400W, 750W, 1KW
Note 2: Sensors are installed on the right or left

SENSOR outlet numbers are as follows:

  1. Positive limit +LS
  2. Point HOME
  3. Negative limit -LS