Unit: mm
|
Load |
0° |
45° |
90° |
|
Horizontal |
1 Kg |
380 |
400 |
450 |
2 Kg |
220 |
250 |
270 |
3 Kg |
160 |
190 |
200 |
4 Kg |
120 |
140 |
150 |
5 Kg |
100 |
110 |
130 |
Wall hanging |
1 Kg |
440 |
390 |
320 |
2 Kg |
260 |
230 |
180 |
3 Kg |
180 |
170 |
120 |
Resolution |
0.001 mm (HEIDENHAIN, RENISHAW) |
Rated thrust |
17 N |
Acceleration thrust |
90 N |
Rated current |
0.51 A |
Accelerating current |
2.7 A |
Thrust constant |
33 |
Back E.M.F. constant |
11 V/ m/ s |
Line resistance |
55 Ω |
Line inductance |
24 mH |
Magnetic pole distance |
60 mm |
Max. acceleration |
3.5 G |
Max. speed |
3 m/s |
Repeat precision |
±0.0005 mm |
Max. load |
Horizontal |
5 kg |
Wall hanging |
3 kg |
Effective stroke |
100~1300 mm (100 Interval) |
Power supply |
220 V |
Working temperature |
0~40 °C |
Storage temperature |
-20~60 °C |
JDLM-130SF-16 Specification